National Stock Number (NSN) Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
9T53Y9088 | 03512 | F | 5 | 2 | 6 | ZZ | ||
9T5349088 | 03512 | F | 5 | 9 | 6 | ZZ | ||
573A499FZP6 | 03497 | A | 3 | 2 | A | TX | ||
573A499FZ66 | 03497 | A | 5 | 9 | 6 | TX | ||
9T53Y9088 | 03497 | A | 5 | 9 | 5 | TX | ||
9T53Y9088 | 60668 | F | C | 1 | 6 | ZZ | AC |
CAGE Information
Code | Company |
---|---|
03497 | GENERAL ELECTRIC CO OUTDOOR BREAKER |
03512 | GENERAL ELECTRIC CO SPECIALTY TRANSF |
60668 | K ELECTRONICS INC. DBA KELECTRONICS |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
ABKW | OVERALL HEIGHT | 4.400 INCHES NOMINAL |
PKWT | UNPACKAGED UNIT WEIGHT (NON-CORE) | 7.000 POUNDS |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
ABMK | OVERALL WIDTH | 3.880 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
CWJS | WINDING OPERATING VOLTAGE | 440.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ABTB | MOUNTING HOLE DIAMETER | 0.215 INCHES MINIMUM SINGLE GROUP AND 0.223 INCHES MAXIMUM SINGLE GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.090 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.150 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.720 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.780 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABHP | OVERALL LENGTH | 5.240 INCHES NOMINAL |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
TTQY | TERMINAL TYPE AND QUANTITY | 4 TAB, SOLDER LUG |