National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
TRANSFORMER , POWER
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number |
CAGE |
Status |
RNCC |
RNVC |
DAC |
RNAAC |
MSDS |
SADC |
W2RBS62 |
13850 |
A |
5 |
2 |
5 |
9Z |
|
|
200BS62 |
13850 |
A |
3 |
2 |
5 |
9Z |
|
|
W2RBS62 |
24655 |
A |
5 |
9 |
5 |
9Z |
|
|
200BS62 |
24655 |
A |
5 |
9 |
5 |
9Z |
|
|
CAGE Information
Code |
Company |
13850 |
TECHNIPOWER LLC DBA INTEGRATED POWER |
24655 |
GENRAD INC |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
ACZB |
FREQUENCY RATING |
50.0 HERTZ MINIMUM SINGLE COMPONENT AND 400.0 HERTZ MAXIMUM SINGLE COMPONENT |
BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY, VARIABLE AUTOTRANSFORMER TYPE SINGLE COMPONENT |
AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
CQLC |
WINDING TAP LOCATION (NON-CORE) |
TAP W/O CENTER TAP SINGLE COMPONENT SINGLE SECONDARY |
AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
ADAR |
BODY OUTSIDE DIAMETER |
3.312 INCHES NOMINAL |
CRBZ |
WINDING OPERATING CURRENT |
1.5 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE SECONDARY |
CRMJ |
WINDING POWER RATING |
170.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY |
CWJS |
WINDING OPERATING VOLTAGE |
115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ |
BODY LENGTH |
3.031 INCHES NOMINAL |
CWJS |
WINDING OPERATING VOLTAGE |
50.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY OR 58.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
TTQY |
TERMINAL TYPE AND QUANTITY |
5 TAB, SOLDER LUG |