National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
TRANSFORMER , POWER AUTOTRANSFORME

Definition:

A TRANSFORMER WHICH INCORPORATES THE PRIMARY AND SECONDARY FUNCTIONS INTO A SINGLE WINDING, WHICH IS COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, AND IS DESIGNED TO CHANGE THE RELATIONSHIP OF VOLTS AND AMPERES BETWEEN THE ENTIRE WINDING AND ITS TAPS. INCLUDES MULTIPLE WINDING TRANSFORMERS OF LIKE DESIGN AND ITEMS IN WHICH A VARIATION OF THE TURNS RATIO OR INDUCTIVE RATIO OF INDUCTIVE COUPLING IS ACCOMPLISHED BY CONNECTION TO FIXED TERMINALS. ALSO, INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO IN PROGRESSIVE INCREMENTS, BY MEANS OF A SHAFT, VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OF SIMILAR DESIGN. EXCLUDES TRANSFORMER (1), POWER; TRANSFORMER (1), PULSE.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
E7466 03776 F 5 9 5 TX
1472865 10001 A 3 2 1 TX
1472865 95036 F 5 9 5 TX
E7466 80223 A 5 9 5 ZZ
E7466 15634 A 3 2 5 ZZ

CAGE Information

Code Company
03776 ESCO INC
10001 NAVAIR AND NAVSEA MANAGED ORIGINAL D
95036 APPLIED DEVICES CORP
80223 UNITED TRANSFORMER CORP SUB OF OPT I
15634 MAGNETIKA INC

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
CQLC WINDING TAP LOCATION (NON-CORE) MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY OUTPUT
CRMJ WINDING POWER RATING 172.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY INPUT
ADAT BODY WIDTH 1.875 INCHES NOMINAL
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CRBZ WINDING OPERATING CURRENT 1.5 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY INPUT
ADAQ BODY LENGTH 1.562 INCHES NOMINAL
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
AXGY MOUNTING METHOD FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY INPUT
AARG RELIABILITY INDICATOR NOT ESTABLISHED
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY, FIXED AUTOTRANSFORMER TYPE SINGLE COMPONENT
TTQY TERMINAL TYPE AND QUANTITY 8 TAB, SOLDER LUG
ACZB FREQUENCY RATING 60.0 HERTZ MAXIMUM SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 65.60 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY OUTPUT AND 32.80 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY OUTPUT AND 82.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY OUTPUT AND 16.40 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY OUTPUT AND 49.20 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY OUTPUT AND 98.40 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY OUTPUT
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
ADAU BODY HEIGHT 1.625 INCHES NOMINAL
AKNA INCLOSURE TYPE OPEN

Similar Parts

E7466 , E7466 , 5950-00-538-1235 , 5950005381235 , 005381235 , E7466 , 1472865 , 1472865 , E7466 , E7466 ,