National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
T29601 00062 A 3 2 1 TX
PMT78 00062 A 5 2 5 TX

CAGE Information

Code Company
00062 MARINE ELECTRIC SYSTEMS INC. DBA MES

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT 3RD SECONDARY
AKNA INCLOSURE TYPE FULLY INCLOSED
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 148.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
ADAT BODY WIDTH 2.125 INCHES NOMINAL
ADAQ BODY LENGTH 3.500 INCHES NOMINAL
AARG RELIABILITY INDICATOR NOT ESTABLISHED
ADAU BODY HEIGHT 2.750 INCHES NOMINAL
CWJS WINDING OPERATING VOLTAGE 20.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY
CWJS WINDING OPERATING VOLTAGE 42.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT 2ND SECONDARY
TTQY TERMINAL TYPE AND QUANTITY 10 WIRE LEAD
AXGY MOUNTING METHOD TERMINAL SINGLE GROUP
ACZB FREQUENCY RATING 60.0 HERTZ NOMINAL SINGLE COMPONENT

Similar Parts

PMT78 , PMT78 , 5950-00-584-0642 , 5950005840642 , 005840642 , T29601 , PMT78 ,