National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
TRANSFORMER , AUDIO FREQUENCY
Definition:
A TRANSFORMER WHICH IS DESIGNED SO THAT PART OR ALL OF ITS RANGE OF OPERATING FREQUENCIES IS 20 KILOHERTZ (KILOCYCLES) AND BELOW. THE MAXIMUM VALUE MAY EXTEND INTO THE RADIO FREQUENCY RANGE. IT IS GENERALLY USED IN THE INPUT, OUTPUT, AMPLIFIER, OR OSCILLATOR STAGES OF AUDIO AND SONAR DEVICES.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
D170116 | 64959 | R | 3 | 9 | X | XX | ||
D170116 | 06KW9 | R | 3 | 2 | 5 | ZZ | ||
D170116 | 70408 | F | 5 | 9 | 5 | TX |
CAGE Information
Code | Company |
---|---|
06KW9 | LUCENT TECHNOLOGIES INC DBA FEDERAL |
64959 | AMERICAN TELEPHONE AND TELEGRAPH CO |
70408 | AT AND T CORP |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AXGY | MOUNTING METHOD | UNTHREADED STUD SINGLE GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ADAU | BODY HEIGHT | 4.688 INCHES NOMINAL |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ADAQ | BODY LENGTH | 4.250 INCHES NOMINAL |
ACYW | IMPEDANCE RATING IN OHMS | 125000.0 NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
ADAT | BODY WIDTH | 2.562 INCHES NOMINAL |
ACYE | TRANSFORMER FUNCTION | INPUT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CQLC | WINDING TAP LOCATION (NON-CORE) | MULTIPLE TAPS W/CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
AKPV | MOUNTING FACILITY QUANTITY | 8 SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 10 WIRE LEAD |
ACZB | FREQUENCY RATING | 10.0 KILOHERTZ MINIMUM SINGLE COMPONENT AND 100.0 KILOHERTZ MAXIMUM SINGLE COMPONENT |
ACYW | IMPEDANCE RATING IN OHMS | 2200.0 NOMINAL SINGLE COMPONENT SINGLE PRIMARY |