Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
SP1027 64959 R 3 9 5 TX
SP1027 06KW9 R 3 2 5 ZZ
BC6674 53292 A 5 2 6 TX
SP1027 70408 F 5 9 5 TX

CAGE Information

Code Company
06KW9 LUCENT TECHNOLOGIES INC DBA FEDERAL
64959 AMERICAN TELEPHONE AND TELEGRAPH CO
53292 PEGASUS INC
70408 AT AND T CORP

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY
AKNA INCLOSURE TYPE FULLY INCLOSED
ADAT BODY WIDTH 3.688 INCHES NOMINAL
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CRBZ WINDING OPERATING CURRENT 700.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE SECONDARY
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
AXGY MOUNTING METHOD THREADED STUD SINGLE GROUP
ADAQ BODY LENGTH 4.625 INCHES NOMINAL
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
ADAU BODY HEIGHT 4.562 INCHES NOMINAL
ACZB FREQUENCY RATING 60.0 HERTZ NOMINAL SINGLE COMPONENT
TTQY TERMINAL TYPE AND QUANTITY 4 TAB, SOLDER LUG

Similar Parts

SP1027 , SP1027 , 5950-00-648-0215 , 5950006480215 , 006480215 , SP1027 , SP1027 , BC6674 , SP1027 ,