National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
TRANSFORMER , POWER
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number |
CAGE |
Status |
RNCC |
RNVC |
DAC |
RNAAC |
MSDS |
SADC |
EP2716 |
23616 |
A |
3 |
2 |
X |
XX |
|
|
CAGE Information
Code |
Company |
23616 |
EPCO PRODUCTS CO |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
ACZB |
FREQUENCY RATING |
50.0 HERTZ MINIMUM SINGLE COMPONENT AND 60.0 HERTZ MAXIMUM SINGLE COMPONENT |
AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
CRBZ |
WINDING OPERATING CURRENT |
150.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
5.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ADAT |
BODY WIDTH |
4.250 INCHES NOMINAL |
CWJS |
WINDING OPERATING VOLTAGE |
6.40 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
ADAQ |
BODY LENGTH |
6.750 INCHES NOMINAL |
AXGY |
MOUNTING METHOD |
FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
CWJS |
WINDING OPERATING VOLTAGE |
190.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 200.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 220.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 210.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 230.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY OR 240.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
FEAT |
SPECIAL FEATURES |
CASE METAL MATERIAL |
AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
CRBZ |
WINDING OPERATING CURRENT |
8.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
ADAU |
BODY HEIGHT |
5.875 INCHES NOMINAL |
ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
2.781 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CQLC |
WINDING TAP LOCATION (NON-CORE) |
CENTER TAP SINGLE COMPONENT 1ST SECONDARY |
ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CQLC |
WINDING TAP LOCATION (NON-CORE) |
CENTER TAP SINGLE COMPONENT 2ND SECONDARY |
CWJS |
WINDING OPERATING VOLTAGE |
3.40 AC MINOR WET SINGLE COMPONENT 2ND SECONDARY |
TTQY |
TERMINAL TYPE AND QUANTITY |
13 TAB, SOLDER LUG |
CQLC |
WINDING TAP LOCATION (NON-CORE) |
MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
ABTB |
MOUNTING HOLE DIAMETER |
0.250 INCHES NOMINAL SINGLE GROUP |
Similar Parts