National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
TRANSFORMER , POWER
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number |
CAGE |
Status |
RNCC |
RNVC |
DAC |
RNAAC |
MSDS |
SADC |
100695 |
79466 |
A |
5 |
2 |
X |
XX |
|
|
638-603 |
75138 |
F |
3 |
2 |
X |
XX |
|
|
608-603 |
75138 |
F |
5 |
9 |
X |
XX |
|
|
CAGE Information
Code |
Company |
75138 |
SHERJOR INC |
79466 |
AESYS TECHNOLOGIES L.L.C. DBA JACKSO |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
AXGY |
MOUNTING METHOD |
FLANGE SINGLE GROUP AND SLOT SINGLE GROUP |
CWJS |
WINDING OPERATING VOLTAGE |
10.00 AC MINOR WET SINGLE COMPONENT SINGLE SECONDARY |
ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
7.062 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
ADAU |
BODY HEIGHT |
5.000 INCHES NOMINAL |
TTQY |
TERMINAL TYPE AND QUANTITY |
2 STANDOFF, THREADED STUD AND 2 WIRE LEAD |
ADAT |
BODY WIDTH |
5.000 INCHES NOMINAL |
AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
ADAQ |
BODY LENGTH |
7.625 INCHES NOMINAL |
CRBZ |
WINDING OPERATING CURRENT |
23.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE SECONDARY |
BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CWJS |
WINDING OPERATING VOLTAGE |
240.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
3.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB |
FREQUENCY RATING |
60.0 HERTZ NOMINAL SINGLE COMPONENT |