National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
SM-A-374628 01534 A 5 2 5 TX
SMLA-374628 80063 A 3 2 1 TX

CAGE Information

Code Company
01534 RAYTHEON COMPANY DBA RAYTHEON
80063 US ARMY COMMUNICATIONS & ELECTRONICS

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CWJS WINDING OPERATING VOLTAGE 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 230.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
CQLC WINDING TAP LOCATION (NON-CORE) TAP W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY
ADAU BODY HEIGHT 2.600 INCHES MAXIMUM
TTQY TERMINAL TYPE AND QUANTITY 10 PIN
CRBZ WINDING OPERATING CURRENT 205.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY
THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.900 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
AEHZ MAXIMUM OPERATING TEMP 105.0 DEG CELSIUS
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND SINGLE GROUP
ADAQ BODY LENGTH 2.750 INCHES NOMINAL
CRBZ WINDING OPERATING CURRENT 430.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT ALL SECONDARY
AARG RELIABILITY INDICATOR NOT ESTABLISHED
ACZB FREQUENCY RATING 57.0 HERTZ MINIMUM SINGLE COMPONENT AND 63.0 HERTZ MAXIMUM SINGLE COMPONENT
CQJX NOMINAL THREAD SIZE 0.138 INCHES SINGLE GROUP
AKNA INCLOSURE TYPE HERMETICALLY SEALED
AXGY MOUNTING METHOD THREADED STUD SINGLE GROUP
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 28.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
CWJS WINDING OPERATING VOLTAGE 43.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
CMLP THREAD QUANTITY PER INCH 32 SINGLE GROUP
AAJD THREAD CLASS (NON-CORE) 2A SINGLE GROUP
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ADAT BODY WIDTH 2.400 INCHES NOMINAL

Similar Parts