National Stock Number (NSN) Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
9142081 | 18876 | A | 3 | 2 | A | TX | ||
PEI 5505 | 13483 | A | 5 | 2 | 5 | ZZ |
CAGE Information
Code | Company |
---|---|
13483 | PRECISION ELECTRONICS INC. |
18876 | U S ARMY AVIATION AND MISSILE COMMAN |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT 3RD SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 12 PIN |
CWJS | WINDING OPERATING VOLTAGE | 12.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 4.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH PRIMARY |
ADAR | BODY OUTSIDE DIAMETER | 2.302 INCHES MINIMUM AND 2.318 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CWJS | WINDING OPERATING VOLTAGE | 4.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND PRIMARY |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 9.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST PRIMARY |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 4 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 60.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD PRIMARY |
ABHP | OVERALL LENGTH | 1.532 INCHES MINIMUM AND 1.612 INCHES MAXIMUM |