National Stock Number (NSN) Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
04284E | 31751 | A | 3 | 2 | 1 | TX |
CAGE Information
Code | Company |
---|---|
31751 | ELTEK ENERGY LLC |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 7 WIRE LEAD |
ABKW | OVERALL HEIGHT | 6.750 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ADAU | BODY HEIGHT | 6.000 INCHES NOMINAL |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 27.60 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 208.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ADAT | BODY WIDTH | 5.875 INCHES NOMINAL |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 100.40 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT SINGLE SECONDARY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 5.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ABTB | MOUNTING HOLE DIAMETER | 0.188 INCHES NOMINAL SINGLE GROUP |
ADAQ | BODY LENGTH | 7.375 INCHES NOMINAL |
CQLC | WINDING TAP LOCATION (NON-CORE) | MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |