National Stock Number (NSN) Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
MIL-T-27/54 | 81349 | M | 5 | 9 | E | TX | ||
MIL-PRF-27/54 | 81349 | M | 4 | 1 | E | ZZ | ||
051992 | 34228 | A | E | 8 | A | TX | ||
TW9D26X | 02640 | A | E | 8 | 5 | ZZ | ||
887D051992 | 34228 | A | 5 | 9 | A | TX | ||
887D051992 | 03956 | A | E | 8 | 5 | TX | ||
M27/54-18A | 81349 | M | 2 | 2 | E | TX | ||
1208546-18 | 56232 | A | C | 1 | 6 | ZZ | AC | |
887F050052 ITEM 19 | 34228 | A | E | 8 | 5 | HD |
CAGE Information
Code | Company |
---|---|
02640 | MAGNETIKA |
81349 | MILITARY SPECIFICATIONS PROMULGATED |
34228 | KOLLMORGEN CORPORATION DBA KOLLMORGE |
03956 | NORTHROP GRUMMAN SYSTEMS CORPORATION |
56232 | LOCKHEED MARTIN CORPORATION DBA LOCK |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ACZF | MAXIMUM TRANSFORMER POWER RATING | 9.0 VOLT-AMPERE SINGLE COMPONENT |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-T-27/54 GOVERNMENT SPECIFICATION |
TEST | TEST DATA DOCUMENT | 81349-MIL-T-27 SPECIFICATION |
CRBZ | WINDING OPERATING CURRENT | 346.0 MILLIAMPERES NOMINAL B SINGLE COMPONENT SINGLE SECONDARY |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
ADAQ | BODY LENGTH | 1.031 INCHES MINIMUM AND 1.093 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
ADAR | BODY OUTSIDE DIAMETER | 0.969 INCHES MINIMUM AND 1.031 INCHES MAXIMUM |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
PKWT | UNPACKAGED UNIT WEIGHT (NON-CORE) | 2.300 OUNCES |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT SINGLE SECONDARY |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
TTQY | TERMINAL TYPE AND QUANTITY | 5 FEED THRU |
AAJD | THREAD CLASS (NON-CORE) | 2A SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 26.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |