National Stock Number (NSN) Output Data
Definition:
AN ITEM GENERALLY CONSISTING OF ONE OR MORE TURNS OF WIRE OR SIMILAR CONDUCTIVE MATERIAL (IN SPECIAL CASES IT MAY BE CONSIDERED AS A PARTIAL TURN). IT IS SPECIFICALLY DESIGNED TO CONCENTRATE MAGNETIC FLUX GENERATED BY THE FLOW OF AN ELECTRIC CURRENT, TO INDUCE IN ITSELF AN ELECTROMOTIVE FORCE, AND TO ADD OR SUBTRACT INDUCTIVE REACTANCE IN A CIRCUIT. IT MAY INCLUDE TUNING DEVICES, INTEGRAL RESISTORS AND CAPACITORS; HOWEVER, EXCLUDES FILTER (AS MODIFIED). FOR COILS WOUND ON RESISTORS WHICH ARE DESIGNED TO BE INSERTED INTO THE CIRCUIT OF A RADIO FREQUENCY STAGE TO SUPPRESS HIGH FREQUENCY PARASITIC OSCILLATIONS, SEE SUPPRESSOR, PARASITIC..
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
21567 | 54241 | A | 3 | 2 | A | TX | ||
M1292 | 54241 | A | 5 | 2 | 5 | TX |
CAGE Information
Code | Company |
---|---|
54241 | MYERS POWER PRODUCTS INC. DBA MYERS/ |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKNA | INCLOSURE TYPE | PARTIALLY INCLOSED, DOUBLE SHELL |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG |
AKDX | WINDING QUANTITY | 1 SINGLE COMPONENT |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
PKWT | UNPACKAGED UNIT WEIGHT (NON-CORE) | 7.250 POUNDS |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CRBZ | WINDING OPERATING CURRENT | 4.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE WINDING |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ADAT | BODY WIDTH | 3.780 INCHES NOMINAL |
ADAQ | BODY LENGTH | 4.500 INCHES NOMINAL |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.030 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
AAJD | THREAD CLASS (NON-CORE) | 2A SINGLE GROUP |
ADAU | BODY HEIGHT | 3.000 INCHES MAXIMUM |
AKPV | MOUNTING FACILITY QUANTITY | 4 ALL GROUPINGS |
ACYV | INDUCTANCE RATING | 100.00 MILLIHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING |