National Stock Number (NSN) Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
160-11553-1 | 3BC99 | A | C | 1 | 5 | 9F | ||
160-11553-1 | 12175 | R | 5 | 9 | 5 | BF | ||
D5-19-6447 | 81361 | A | 3 | 2 | A | TX |
CAGE Information
Code | Company |
---|---|
12175 | UNITRON INC |
3BC99 | UNITRON LP |
81361 | EDGEWOOD CHEMICAL BIOLOGICAL CENTER |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ADAU | BODY HEIGHT | 1.500 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
TTQY | TERMINAL TYPE AND QUANTITY | 11 TAB, SOLDER LUG |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 14.00 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL SECONDARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.200 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AXGY | MOUNTING METHOD | BRACKET SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 300.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT ALL SECONDARY |
ADAQ | BODY LENGTH | 2.650 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.199 INCHES NOMINAL SINGLE GROUP |
ADAT | BODY WIDTH | 1.500 INCHES MAXIMUM |
PKWT | UNPACKAGED UNIT WEIGHT (NON-CORE) | 8.000 OUNCES |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 56.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |