National Stock Number (NSN) Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
MIL-T-27/325 | 81349 | M | 4 | 1 | E | TX | ||
M27/325-03 | 81349 | M | 2 | 2 | E | TX |
CAGE Information
Code | Company |
---|---|
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CWJS | WINDING OPERATING VOLTAGE | 9.00 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL SECONDARY AND 6.00 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL SECONDARY AND 15.00 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL SECONDARY |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AFHM | MOUNTING TAB WIDTH | 0.032 INCHES NOMINAL |
ADAT | BODY WIDTH | 1.210 INCHES MINIMUM AND 1.270 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 1.210 INCHES MINIMUM AND 1.270 INCHES MAXIMUM |
AXGY | MOUNTING METHOD | TAB SINGLE GROUP |
TEST | TEST DATA DOCUMENT | 81349-MIL-T-27 SPECIFICATION |
ADAU | BODY HEIGHT | 0.590 INCHES MINIMUM AND 0.650 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.958 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 0.978 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
PKWT | UNPACKAGED UNIT WEIGHT (NON-CORE) | 56.7 GRAMS |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-T-27/325 GOVERNMENT SPECIFICATION |
CRBZ | WINDING OPERATING CURRENT | 330.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT ALL SECONDARY |
CQLC | WINDING TAP LOCATION (NON-CORE) | TAP W/O CENTER TAP SINGLE COMPONENT ALL SECONDARY |