National Stock Number (NSN) Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
10315 | 31669 | A | 3 | 1 | 5 | TX | ||
42-3595-3 | 27192 | A | 5 | 1 | A | TX | ||
LO4423 | 16236 | A | 5 | 2 | A | ZZ |
CAGE Information
Code | Company |
---|---|
16236 | DLA LAND AND MARITIME |
31669 | PICO ELECTRONICS INC. |
27192 | DRS POWER & CONTROL TECHNOLOGIES INC |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CRTL | CRITICALITY CODE JUSTIFICATION | ZZZY |
FEAT | SPECIAL FEATURES | ITEM MUST COMPLY WITH REQUIREMENTS OF DEFENSE SUPPLY CENTER COLUMBUS PRODUCTION STANDARD NO. LO4423 |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ADAV | OVERALL DIAMETER | 0.800 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.500 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
TTQY | TERMINAL TYPE AND QUANTITY | 6 WIRE LEAD |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | BREFERENCE NUMBER DIFFERENTIATING MATERIAL WILL BE IN ACCORDANCE WITH NAVAL INVENTORY CONTROL POINT ACTIVITY HX QUALITY CONTROL. MANUFACTURING AND TESTING SPECIFICATIONS AVAILABLE AT THE DLA ICP. |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |