Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
5495830 53711 A 3 2 A ZZ
272.404 431 D3683 A 5 2 1 ZG
DGM/M-10200VA-50HZ-40071034462 D1739 A 5 2 5 ZZ

CAGE Information

Code Company
53711 NAVAL SEA SYSTEMS COMMAND
D3683 ESW GMBH
D1739 COOPER CROUSE-HINDS GMBH STANDORT EB

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AXGY MOUNTING METHOD UNTHREADED HOLE 1ST GROUP
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 57.0 MILLIMETERS NOMINAL ALL MOUNTING FACILITIES 2ND CENTER GROUP
CRBZ WINDING OPERATING CURRENT 82.0 AMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT SINGLE SECONDARY
ABHP OVERALL LENGTH 410.0 MILLIMETERS NOMINAL
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 260.0 MILLIMETERS NOMINAL ALL MOUNTING FACILITIES 1ST CENTER GROUP
CBBL FEATURES PROVIDED W/RESISTOR
AKNA INCLOSURE TYPE FULLY INCLOSED
FEAT SPECIAL FEATURES IN MRC CBBL RESISTORS ARE VARIBLE
ACZD TRANSFORMER WINDING CONNECTION TYPE DELTA-WYE
CWJS WINDING OPERATING VOLTAGE 440.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
ABMK OVERALL WIDTH 173.0 MILLIMETERS NOMINAL
ABTB MOUNTING HOLE DIAMETER 16.0 MILLIMETERS NOMINAL 1ST GROUP
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 165.0 MILLIMETERS MAXIMUM ALL MOUNTING FACILITIES 1ST CENTER GROUP
CQLC WINDING TAP LOCATION (NON-CORE) NEUTRAL TAP SINGLE COMPONENT SINGLE SECONDARY
AKPV MOUNTING FACILITY QUANTITY 6 2ND GROUP
AARG RELIABILITY INDICATOR NOT ESTABLISHED
CRMJ WINDING POWER RATING 10.2 K1LOVOLT-AMPERES SINGLE COMPONENT SINGLE SECONDARY
CWJS WINDING OPERATING VOLTAGE 125.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY
AEHZ MAXIMUM OPERATING TEMP 65.0 DEG CELSIUS
ABKW OVERALL HEIGHT 267.0 MILLIMETERS NOMINAL
ABTD MOUNTING SLOT WIDTH 11.0 MILLIMETERS NOMINAL 2ND GROUP
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT
ACZC INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO SIX PHASE SINGLE COMPONENT
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
AKPV MOUNTING FACILITY QUANTITY 4 1ST GROUP
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 130.0 MILLIMETERS NOMINAL ALL MOUNTING FACILITIES 2ND CENTER GROUP
TTQY TERMINAL TYPE AND QUANTITY 2 TERMINAL BLOCK W/SCREWS
AXGY MOUNTING METHOD SLOT 2ND GROUP
ACZB FREQUENCY RATING 60.0 HERTZ NOMINAL SINGLE COMPONENT

Similar Parts

5495830 , 5495830 , 5950-01-380-0936 , 5950013800936 , 013800936 , 5495830 , 272.404 431 , DGM/M-10200VA-50HZ-40071034462 ,