National Stock Number (NSN) Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
5495828 | 53711 | A | 3 | 2 | A | ZZ | ||
5495828 | 0JXN5 | F | 5 | 9 | 5 | ZZ | ||
DGM/M-435VA-60HZ 40071034 609 | D1739 | A | 5 | 2 | 5 | ZZ |
CAGE Information
Code | Company |
---|---|
0JXN5 | TRANSLANT INC A JOINT VENTURE |
53711 | NAVAL SEA SYSTEMS COMMAND |
D1739 | COOPER CROUSE-HINDS GMBH STANDORT EB |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
ABHP | OVERALL LENGTH | 164.0 MILLIMETERS MAXIMUM |
ABKW | OVERALL HEIGHT | 155.0 MILLIMETERS NOMINAL |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
CRMJ | WINDING POWER RATING | 435.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY |
ABMK | OVERALL WIDTH | 100.0 MILLIMETERS MAXIMUM |
AXGY | MOUNTING METHOD | SLOT SINGLE GROUP |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO TWELVE PHASE SINGLE COMPONENT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CWJS | WINDING OPERATING VOLTAGE | 33.70 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY AND 14.30 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY AND 14.30 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY AND 33.70 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
FEAT | SPECIAL FEATURES | PRIMARY INTERNAL CONNECTION SPLIT TO PROVIDE DUAL CONNECTION |
AEHZ | MAXIMUM OPERATING TEMP | 65.0 DEG CELSIUS |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 85.0 MILLIMETERS NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CRBZ | WINDING OPERATING CURRENT | 2.5 AMPERES NOMINAL B SINGLE COMPONENT SINGLE SECONDARY AND 2.5 AMPERES NOMINAL B SINGLE COMPONENT SINGLE SECONDARY AND 5.0 AMPERES NOMINAL B SINGLE COMPONENT SINGLE SECONDARY AND 5.0 AMPERES NOMINAL B SINGLE COMPONENT SINGLE SECONDARY |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 3 PRIMARY SINGLE COMPONENT AND 12 SECONDARY SINGLE COMPONENT |
ABTD | MOUNTING SLOT WIDTH | 7.0 MILLIMETERS NOMINAL SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TERMINAL BLOCK W/SCREWS |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |