Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
984691-1 82577 A 3 2 1 TX
41356 73386 A 5 2 5 TX
860834 82577 A 5 2 5 TX

CAGE Information

Code Company
73386 FREED TRANSFORMER COMPANY
82577 RAYTHEON COMPANY DBA RAYTHEON

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKNA INCLOSURE TYPE FULLY INCLOSED
AKNA INCLOSURE TYPE FULLY INCLOSED
AKPV MOUNTING FACILITY QUANTITY 2 SINGLE GROUP
ABHP OVERALL LENGTH 1.620 INCHES NOMINAL
AEJN DISTANCE BETWEEN MOUNTING FACILITY CENTERS 1.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ADAU BODY HEIGHT 0.930 INCHES MAXIMUM
ADAT BODY WIDTH 1.150 INCHES MAXIMUM
AXGY MOUNTING METHOD FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP
ABTB MOUNTING HOLE DIAMETER 0.140 INCHES MINIMUM SINGLE GROUP AND 0.146 INCHES MAXIMUM SINGLE GROUP
AARG RELIABILITY INDICATOR NOT ESTABLISHED
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
ADAQ BODY LENGTH 1.100 INCHES MAXIMUM
CWJS WINDING OPERATING VOLTAGE 6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY
CRBZ WINDING OPERATING CURRENT 600.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE SECONDARY
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
ACZB FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
TTQY TERMINAL TYPE AND QUANTITY 5 TAB, SOLDER LUG

Similar Parts

41356 , 41356 , 5950-00-004-7661 , 5950000047661 , 000047661 , 984691-1 , 41356 , 860834 ,