National Stock Number (NSN) Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
651-1053-000 | 21908 | F | 5 | 9 | 5 | TX | ||
651-1053-000N | 97953 | A | 3 | 2 | A | TX | ||
5043-418 | 05869 | A | 5 | 2 | 5 | TX | ||
PEI 9461 | 13483 | A | 5 | 2 | 5 | ZZ |
CAGE Information
Code | Company |
---|---|
05869 | RAYTHEON COMPANY DBA RAYTHEON |
21908 | NCR CORP POWER SYSTEMS DIV |
97953 | GE AVIATIONS SYSTEMS LLC DBA GE AVIA |
13483 | PRECISION ELECTRONICS INC. |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.200 INCHES NOMINAL 1ST MOUNTING FACILITY 1ST CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.200 INCHES NOMINAL 1ST MOUNTING FACILITY 1ST CENTER GROUP |
AAJD | THREAD CLASS (NON-CORE) | 2B ALL GROUPINGS |
CWJS | WINDING OPERATING VOLTAGE | 17.60 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 17.40 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.800 INCHES NOMINAL 1ST MOUNTING FACILITY 1ST CENTER GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
CWJS | WINDING OPERATING VOLTAGE | 17.40 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND ALL GROUPINGS |
ADAQ | BODY LENGTH | 8.125 INCHES MAXIMUM |
AKPV | MOUNTING FACILITY QUANTITY | 6 1ST GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE ALL GROUPINGS |
CWJS | WINDING OPERATING VOLTAGE | 30.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
TTQY | TERMINAL TYPE AND QUANTITY | 30 THREADED STUD |
CBME | CUBIC MEASURE (NON-CORE) | 216.0 CUBIC INCHES |
ADAT | BODY WIDTH | 4.625 INCHES MAXIMUM |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT AND SINGLE PHASE TO SIX PHASE SINGLE COMPONENT |
CQLC | WINDING TAP LOCATION (NON-CORE) | MULTIPLE TAPS W/O NEUTRAL TAP SINGLE COMPONENT SINGLE PRIMARY |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES ALL GROUPINGS |
ADAU | BODY HEIGHT | 5.750 INCHES MAXIMUM |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 7 SECONDARY SINGLE COMPONENT |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
THSD | THREAD SERIES DESIGNATOR | UNC ALL GROUPINGS |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA AND WYE-WYE |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.500 INCHES NOMINAL 2ND MOUNTING FACILITY 2ND CENTER GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 2ND GROUP |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 7.500 INCHES NOMINAL 2ND MOUNTING FACILITY 2ND CENTER GROUP |
FEAT | SPECIAL FEATURES | 1PRIMARY WINDING; 7 SECONDARY WINDINGS |