National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
TRANSFORMER , AUDIO FREQUENCY
Definition:
A TRANSFORMER WHICH IS DESIGNED SO THAT PART OR ALL OF ITS RANGE OF OPERATING FREQUENCIES IS 20 KILOHERTZ (KILOCYCLES) AND BELOW. THE MAXIMUM VALUE MAY EXTEND INTO THE RADIO FREQUENCY RANGE. IT IS GENERALLY USED IN THE INPUT, OUTPUT, AMPLIFIER, OR OSCILLATOR STAGES OF AUDIO AND SONAR DEVICES.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
4994 | 96253 | F | 3 | 9 | 4 | 48 | ||
A-9292 | 81535 | F | 5 | 9 | 1 | TX | ||
TTI-4994 | 96252 | F | 5 | 9 | 5 | TX |
CAGE Information
Code | Company |
---|---|
81535 | AERONAUTICAL COMMUNICATIONS EQUIPMEN |
96253 | TRANSFORMER TECHNICIANS INC |
96252 | PARK CITY ELECTRONIC LABORATORIES |
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
ADAU | BODY HEIGHT | 2.438 INCHES NOMINAL |
ACYW | IMPEDANCE RATING IN OHMS | 10000.0 NOMINAL SINGLE COMPONENT 2ND SECONDARY |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
ACYW | IMPEDANCE RATING IN OHMS | 125.0 NOMINAL SINGLE COMPONENT ALL PRIMARY |
AAJD | THREAD CLASS (NON-CORE) | 3A SINGLE GROUP |
AFGR | FREQUENCY RESPONSE TOLERANCE IN DECIBELS (NON-CORE) | -10.0/+10.0 SINGLE COMPONENT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 8 SOLDER STUD |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
ADAQ | BODY LENGTH | 1.750 INCHES NOMINAL |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
ADAT | BODY WIDTH | 1.625 INCHES NOMINAL |
CRBZ | WINDING OPERATING CURRENT | 20.0 MICROAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT ALL PRIMARY |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
ACYW | IMPEDANCE RATING IN OHMS | 100.0 NOMINAL SINGLE COMPONENT 1ST SECONDARY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 30.0 MICROAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
ABKW | OVERALL HEIGHT | 2.813 INCHES NOMINAL |