National Stock Number (NSN) Output Data
Definition:
AN ITEM GENERALLY CONSISTING OF ONE OR MORE TURNS OF WIRE OR SIMILAR CONDUCTIVE MATERIAL (IN SPECIAL CASES IT MAY BE CONSIDERED AS A PARTIAL TURN). IT IS SPECIFICALLY DESIGNED TO CONCENTRATE MAGNETIC FLUX GENERATED BY THE FLOW OF AN ELECTRIC CURRENT, TO INDUCE IN ITSELF AN ELECTROMOTIVE FORCE, AND TO ADD OR SUBTRACT INDUCTIVE REACTANCE IN A CIRCUIT. IT MAY INCLUDE TUNING DEVICES, INTEGRAL RESISTORS AND CAPACITORS; HOWEVER, EXCLUDES FILTER (AS MODIFIED). FOR COILS WOUND ON RESISTORS WHICH ARE DESIGNED TO BE INSERTED INTO THE CIRCUIT OF A RADIO FREQUENCY STAGE TO SUPPRESS HIGH FREQUENCY PARASITIC OSCILLATIONS, SEE SUPPRESSOR, PARASITIC..
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
K880962-20 | 49671 | F | 5 | 9 | 5 | ZZ | ||
751S1W26 | 56365 | A | 3 | 2 | X | XX |
CAGE Information
Code | Company |
---|---|
49671 | LOCKHEED MARTIN CORP LOCKHEED MARTIN |
56365 | SCHNEIDER ELECTRIC USA INC. DBA SCHN |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG |
AKDX | WINDING QUANTITY | 1 SINGLE COMPONENT |
ADAR | BODY OUTSIDE DIAMETER | 3.250 INCHES NOMINAL |
CQPZ | WINDING CONDUCTOR SIZE | 0.01594 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT SINGLE WINDING |
ADAQ | BODY LENGTH | 3.000 INCHES NOMINAL |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABTB | MOUNTING HOLE DIAMETER | 1.000 INCHES NOMINAL SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 55.00 DC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE WINDING |
AKPV | MOUNTING FACILITY QUANTITY | 1 SINGLE GROUP |
AKNA | INCLOSURE TYPE | OPEN |
ABHY | TURN QUANTITY | 8000 SINGLE COMPONENT SINGLE WINDING |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING AND WINDING TURNS SINGLE COMPONENT SINGLE WINDING |
CRGS | DC RESISTANCE RATING IN OHMS | 185.000 SINGLE COMPONENT SINGLE WINDING |