Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
T47770 80220 H 5 9 5 TX
T47770 96256 A 3 2 5 TX
ESL640190 64959 R 5 9 A TX
KS8885 64959 R 5 9 5 TX

CAGE Information

Code Company
64959 AMERICAN TELEPHONE AND TELEGRAPH CO
80220 COMPONENTS CORP OF AMERICA
96256 THORDARSON INC

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
ADAT BODY WIDTH 2.688 INCHES NOMINAL
CRBZ WINDING OPERATING CURRENT 3.5 AMPERES NOMINAL B AND BETTER SINGLE COMPONENT 2ND SECONDARY
CWJS WINDING OPERATING VOLTAGE 5.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
AKNA INCLOSURE TYPE FULLY INCLOSED
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT
THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP
CRBZ WINDING OPERATING CURRENT 3.5 AMPERES NOMINAL B AND BETTER SINGLE COMPONENT 3RD SECONDARY
CMLP THREAD QUANTITY PER INCH 20 SINGLE GROUP
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND SINGLE GROUP
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CRBZ WINDING OPERATING CURRENT 10.0 AMPERES NOMINAL B AND BETTER SINGLE COMPONENT 1ST SECONDARY
CWJS WINDING OPERATING VOLTAGE 1.75 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
AARG RELIABILITY INDICATOR NOT ESTABLISHED
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ACZB FREQUENCY RATING 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT
AXGY MOUNTING METHOD THREADED STUD SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY
ADAQ BODY LENGTH 4.594 INCHES NOMINAL
TTQY TERMINAL TYPE AND QUANTITY 8 STANDOFF, SOLDER LUG
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
ADAU BODY HEIGHT 5.312 INCHES NOMINAL
AAJD THREAD CLASS (NON-CORE) 2A SINGLE GROUP
CQJX NOMINAL THREAD SIZE 0.250 INCHES SINGLE GROUP

Similar Parts

ESL640190 , ESL640190 , 5950-00-247-8038 , 5950002478038 , 002478038 , T47770 , T47770 , ESL640190 , KS8885 ,