National Stock Number (NSN) Output Data
Definition:
AN ITEM GENERALLY CONSISTING OF ONE OR MORE TURNS OF WIRE OR SIMILAR CONDUCTIVE MATERIAL (IN SPECIAL CASES IT MAY BE CONSIDERED AS A PARTIAL TURN). IT IS SPECIFICALLY DESIGNED TO CONCENTRATE MAGNETIC FLUX GENERATED BY THE FLOW OF AN ELECTRIC CURRENT, TO INDUCE IN ITSELF AN ELECTROMOTIVE FORCE, AND TO ADD OR SUBTRACT INDUCTIVE REACTANCE IN A CIRCUIT. IT MAY INCLUDE TUNING DEVICES, INTEGRAL RESISTORS AND CAPACITORS; HOWEVER, EXCLUDES FILTER (AS MODIFIED). FOR COILS WOUND ON RESISTORS WHICH ARE DESIGNED TO BE INSERTED INTO THE CIRCUIT OF A RADIO FREQUENCY STAGE TO SUPPRESS HIGH FREQUENCY PARASITIC OSCILLATIONS, SEE SUPPRESSOR, PARASITIC..
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
19736 | 24975 | A | 3 | 2 | 5 | ZZ | ||
R149019736 | 35510 | R | 5 | 9 | X | XX | ||
19736 | 35510 | R | 5 | 9 | X | XX | ||
R149019736 | 24975 | A | 5 | 2 | 5 | ZZ |
CAGE Information
Code | Company |
---|---|
24975 | PRESTOLITE ELECTRIC INCORPORATED |
35510 | PRESTOLITE ELECTRIC INC |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CRGS | DC RESISTANCE RATING IN OHMS | 0.750 SINGLE COMPONENT 3RD WINDING |
CRGS | DC RESISTANCE RATING IN OHMS | 0.750 SINGLE COMPONENT 3RD WINDING |
AKDX | WINDING QUANTITY | 4 SINGLE COMPONENT |
AAJD | THREAD CLASS (NON-CORE) | 2B SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 24.00 DC POUNDS PER HOUR WET SINGLE COMPONENT ALL WINDING |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
ADAR | BODY OUTSIDE DIAMETER | 1.500 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.500 INCHES NOMINAL |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.37 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 1ST WINDING |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
CRGS | DC RESISTANCE RATING IN OHMS | 17.500 SINGLE COMPONENT 1ST WINDING |
TTQY | TERMINAL TYPE AND QUANTITY | 8 WIRE LEAD |
CRBZ | WINDING OPERATING CURRENT | 275.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 2ND WINDING |
ACZR | CORE CONSTRUCTION | S0LID SINGLE COMPONENT |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE GROUP |
CRGS | DC RESISTANCE RATING IN OHMS | 87.000 SINGLE COMPONENT 2ND WINDING |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 32.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 3RD WINDING |