National Stock Number (NSN) Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
121101 | 72149 | A | 5 | 2 | 5 | TX | ||
S510044 | 72149 | A | 5 | 2 | 5 | TX | ||
401590 | 12909 | R | 5 | 9 | 1 | TX | ||
401590 | 20284 | A | 3 | 2 | 1 | TX |
CAGE Information
Code | Company |
---|---|
12909 | CARDION INC |
72149 | ELECTRONIC TRANSFORMER CORP. |
20284 | TARGET CORPORATION DBA TARGET |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CWJS | WINDING OPERATING VOLTAGE | 6.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 6 TAB, SOLDER LUG |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 105.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 125.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
ABHP | OVERALL LENGTH | 1.750 INCHES MAXIMUM |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.437 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ADAT | BODY WIDTH | 0.800 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 0.844 INCHES NOMINAL |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
ADAQ | BODY LENGTH | 1.100 INCHES MAXIMUM |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
ABMK | OVERALL WIDTH | 0.800 INCHES MAXIMUM |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZB | FREQUENCY RATING | 54.0 HERTZ MINIMUM SINGLE COMPONENT AND 440.0 HERTZ MAXIMUM SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 1.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE SECONDARY |
ABTB | MOUNTING HOLE DIAMETER | 0.140 INCHES NOMINAL SINGLE GROUP |
CQLC | WINDING TAP LOCATION (NON-CORE) | MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
AEHZ | MAXIMUM OPERATING TEMP | 110.0 DEG CELSIUS |
ADAU | BODY HEIGHT | 0.844 INCHES NOMINAL |