National Stock Number (NSN) Output Data
Definition:
AN ITEM CONSISTING OF A PARTIAL TURN AS ONE OR MORE TURNS OF WIRE OR OTHER CONDUCTIVE MATERIAL WHICH CONSTITUTES ONE CONTINUOUS UNTAPPED WINDING. IT MAY BE WOUND OR FORMED IN OTHER THAN A CIRCULAR MANNER AND MAY BE SELF-SUPPORTING, REQUIRING NO COIL FORM. IT IS SPECIFICALLY DESIGNED TO FURNISH INDUCTIVE REACTANCE IN A CIRCUIT CARRYING RADIO FREQUENCY CURRENT RANGING FROM 20 KILOHERTZ (KILOCYCLES) AND ABOVE. IT MAY INCLUDE TUNING DEVICES, INTEGRAL RESISTORS AND CAPACITORS; HOWEVER, EXCLUDES FILTER (AS MODIFIED). THE COIL HAS ONLY TWO ELECTRICAL TERMINALS. FOR ITEMS HAVING TAPPED WINDING OR MORE THAN ONE WINDING - SEE TRANSFORMER, RADIO FREQUENCY. FOR COILS WOUND ON RESISTORS, WHICH ARE DESIGNED TO BE INSERTED IN THE CIRCUIT OF A RADIO FREQUENCY STAGE TO SUPPRESS HIGH FREQUENCY PARASITIC OSCILLATIONS, SEE SUPPRESSOR, PARASITIC.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
3635-53 | 71279 | F | 5 | 9 | 5 | TX | ||
263453-1 | 3SLK7 | A | C | 1 | 5 | ZZ | 9X | |
263453-1 | 96795 | A | 3 | 9 | A | TX |
CAGE Information
Code | Company |
---|---|
3SLK7 | LDS TEST AND MEASUREMENT LLC |
71279 | INTERCONNECTION PRODUCTS INC |
96795 | GOULD INSTRUMENT SYSTEMS INC |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CBME | CUBIC MEASURE (NON-CORE) | 0.036 CUBIC INCHES |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ACYV | INDUCTANCE RATING | 22.00 MILLIHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING |
ACZP | COIL FORM TYPE | SOLID SINGLE COMPONENT |
CRLC | FREQUENCY AT WHICH INDUCTANCE AND QUALITY FACTOR APPLIES (NON-CORE) | 79.0 KILOHERTZ SINGLE COMPONENT SINGLE WINDING |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CRBZ | WINDING OPERATING CURRENT | 10.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE WINDING |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING |
AFGS | MINIMUM SELF-RESONANT FREQUENCY (NON-CORE) | 420.0 KILOHERTZ SINGLE COMPONENT |
CRGS | DC RESISTANCE RATING IN OHMS | 250.000 SINGLE COMPONENT SINGLE WINDING |
ABHP | OVERALL LENGTH | 0.375 INCHES NOMINAL |
ADAV | OVERALL DIAMETER | 0.312 INCHES NOMINAL |
CRHJ | QUALITY FACTOR | 50 MAXIMUM SINGLE COMPONENT SINGLE WINDING |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |