National Stock Number (NSN) Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
20007061 | 72314 | A | 3 | 2 | X | XX |
CAGE Information
Code | Company |
---|---|
72314 | BAE SYSTEMS INFORMATION AND ELECTRON |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 1.75 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 2.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 1.75 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ADAQ | BODY LENGTH | 3.562 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
TTQY | TERMINAL TYPE AND QUANTITY | 9 STANDOFF, SOLDER LUG |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 7.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 3.3 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
ADAU | BODY HEIGHT | 3.875 INCHES NOMINAL |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAT | BODY WIDTH | 3.062 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CWJS | WINDING OPERATING VOLTAGE | 2.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |