National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
TRANSFORMER , AUDIO FREQUENCY
Definition:
A TRANSFORMER WHICH IS DESIGNED SO THAT PART OR ALL OF ITS RANGE OF OPERATING FREQUENCIES IS 20 KILOHERTZ (KILOCYCLES) AND BELOW. THE MAXIMUM VALUE MAY EXTEND INTO THE RADIO FREQUENCY RANGE. IT IS GENERALLY USED IN THE INPUT, OUTPUT, AMPLIFIER, OR OSCILLATOR STAGES OF AUDIO AND SONAR DEVICES.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
SMC185156 | 80063 | A | 3 | 2 | 1 | TX | ||
109-168 | 02470 | H | 5 | 9 | X | XX | ||
18261 | 80089 | F | 5 | 9 | X | XX |
CAGE Information
Code | Company |
---|---|
02470 | AMF INC WORLD HEADQUARTERS |
80063 | US ARMY COMMUNICATIONS & ELECTRONICS |
80089 | EMERSON ELECTRIC CO WHITE-RODGERS DI |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AFGR | FREQUENCY RESPONSE TOLERANCE IN DECIBELS (NON-CORE) | -1.0/+1.0 SINGLE COMPONENT |
AAJD | THREAD CLASS (NON-CORE) | 2B SINGLE GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
TTQY | TERMINAL TYPE AND QUANTITY | 2 STANDOFF, SOLDER LUG AND 3 THREADED STUD |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
CMLP | THREAD QUANTITY PER INCH | 20 SINGLE GROUP |
ADAQ | BODY LENGTH | 5.375 INCHES NOMINAL |
ADAU | BODY HEIGHT | 7.187 INCHES MAXIMUM |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
ACZB | FREQUENCY RATING | 300.0 HERTZ MINIMUM SINGLE COMPONENT AND 3.5 KILOHERTZ MAXIMUM SINGLE COMPONENT |
ADAT | BODY WIDTH | 6.125 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 225.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
ACZH | PRIMARY TO SECONDARY TURN RATIO | 1 TO 2 SINGLE COMPONENT |
ACYW | IMPEDANCE RATING IN OHMS | 20300.0 NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 275.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE SECONDARY |
ACYW | IMPEDANCE RATING IN OHMS | 9100.0 NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 250.0 WATTS SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |