National Stock Number (NSN) Output Data
Definition:
AN ITEM GENERALLY CONSISTING OF ONE OR MORE TURNS OF WIRE OR SIMILAR CONDUCTIVE MATERIAL (IN SPECIAL CASES IT MAY BE CONSIDERED AS A PARTIAL TURN). IT IS SPECIFICALLY DESIGNED TO CONCENTRATE MAGNETIC FLUX GENERATED BY THE FLOW OF AN ELECTRIC CURRENT, TO INDUCE IN ITSELF AN ELECTROMOTIVE FORCE, AND TO ADD OR SUBTRACT INDUCTIVE REACTANCE IN A CIRCUIT. IT MAY INCLUDE TUNING DEVICES, INTEGRAL RESISTORS AND CAPACITORS; HOWEVER, EXCLUDES FILTER (AS MODIFIED). FOR COILS WOUND ON RESISTORS WHICH ARE DESIGNED TO BE INSERTED INTO THE CIRCUIT OF A RADIO FREQUENCY STAGE TO SUPPRESS HIGH FREQUENCY PARASITIC OSCILLATIONS, SEE SUPPRESSOR, PARASITIC..
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
22D47G2 | 24446 | A | 3 | 2 | X | XX | ||
9049295P7 | 71669 | H | 5 | 9 | X | XX | ||
113736PC12 | 10001 | A | 5 | 2 | X | XX | ||
5990499PC12 | 24446 | A | 5 | 2 | X | XX | ||
9049295P7 | 24446 | A | 5 | 2 | X | XX |
CAGE Information
Code | Company |
---|---|
10001 | NAVAIR AND NAVSEA MANAGED ORIGINAL D |
24446 | GENERAL ELECTRIC CO |
71669 | GENERAL ELECTRIC CO SWITCHGEAR AND C |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ADAQ | BODY LENGTH | 0.969 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKDX | WINDING QUANTITY | 1 SINGLE COMPONENT |
ADAR | BODY OUTSIDE DIAMETER | 1.062 INCHES NOMINAL |
ABHY | TURN QUANTITY | 6470 SINGLE COMPONENT SINGLE WINDING |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CQPZ | WINDING CONDUCTOR SIZE | 0.00445 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT SINGLE WINDING |
CRGS | DC RESISTANCE RATING IN OHMS | 810.000 SINGLE COMPONENT SINGLE WINDING |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 110.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE WINDING |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING AND WINDING TURNS SINGLE COMPONENT SINGLE WINDING |