National Stock Number (NSN) Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
9868-260X2SHTIPC122 | 96169 | A | 3 | 2 | E | TX | ||
9827-043X2PC7 | 96169 | A | 5 | 2 | 5 | TX |
CAGE Information
Code | Company |
---|---|
96169 | ELECTRIC BOAT CORPORATION |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
TTQY | TERMINAL TYPE AND QUANTITY | 4 TURRET |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
CWJS | WINDING OPERATING VOLTAGE | 5.00 AC POUNDS PER HOUR DRY SINGLE COMPONENT SINGLE SECONDARY AND 6.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT SINGLE SECONDARY |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.086 INCHES SINGLE GROUP |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.671 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
ADAQ | BODY LENGTH | 1.344 INCHES NOMINAL |
CWJS | WINDING OPERATING VOLTAGE | 117.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AAJD | THREAD CLASS (NON-CORE) | 2A SINGLE GROUP |
ADAU | BODY HEIGHT | 1.353 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.979 INCHES NOMINAL |
ACZB | FREQUENCY RATING | 60.0 HERTZ MINIMUM SINGLE COMPONENT AND 400.0 HERTZ MAXIMUM SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 0.34 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE SECONDARY |