Item Name:
TRANSFORMER , AUDIO FREQUENCY
Definition:
A TRANSFORMER WHICH IS DESIGNED SO THAT PART OR ALL OF ITS RANGE OF OPERATING FREQUENCIES IS 20 KILOHERTZ (KILOCYCLES) AND BELOW. THE MAXIMUM VALUE MAY EXTEND INTO THE RADIO FREQUENCY RANGE. IT IS GENERALLY USED IN THE INPUT, OUTPUT, AMPLIFIER, OR OSCILLATOR STAGES OF AUDIO AND SONAR DEVICES.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
D10405 | 00144 | A | 3 | 9 | 5 | TX | ||
43563 | 73386 | A | 5 | 2 | 5 | TX |
CAGE Information
Code | Company |
---|---|
00144 | ADC TELECOMMUNICATIONS INC. DIV ADC |
73386 | FREED TRANSFORMER COMPANY |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
ACYW | IMPEDANCE RATING IN OHMS | 1000.0 NOMINAL SINGLE COMPONENT ALL SECONDARY |
ADAT | BODY WIDTH | 1.562 INCHES NOMINAL |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
ADAQ | BODY LENGTH | 2.312 INCHES NOMINAL |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT ALL PRIMARY |
ACZB | FREQUENCY RATING | 30.0 HERTZ MAXIMUM SINGLE COMPONENT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.937 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 105.0 MILLIWATTS SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 50.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT ALL PRIMARY |
ACYW | IMPEDANCE RATING IN OHMS | 800.0 NOMINAL SINGLE COMPONENT ALL PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 14 PIN |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ADAU | BODY HEIGHT | 1.800 INCHES NOMINAL |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
ACYE | TRANSFORMER FUNCTION | LINE |
AAJD | THREAD CLASS (NON-CORE) | 2A SINGLE GROUP |