National Stock Number (NSN) Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
C13227 | 72149 | A | 5 | 2 | 5 | TX | ||
172219 | 64196 | F | 5 | 9 | 5 | TX | ||
P3-34330 | 53854 | A | C | 1 | 5 | ZZ | 9X | |
PE8 6315 | 13483 | A | 5 | 2 | 5 | TX | ||
P3-34330 | 95970 | A | 5 | 9 | 5 | TX | ||
42812 | 22558 | A | 5 | 2 | 5 | TX | ||
602B892H01 | 97942 | A | 3 | 2 | 1 | TX | ||
602B892H01 | 89870 | A | 5 | 9 | 5 | TX | ||
BX-10011 | 85323 | A | 5 | 2 | 5 | TX |
CAGE Information
Code | Company |
---|---|
13483 | PRECISION ELECTRONICS INC. |
72149 | ELECTRONIC TRANSFORMER CORP. |
64196 | VOLTAMPERE CORP |
53854 | MAGNESPEC INC. |
95970 | MTE CORP MILWAUKEE TRANSFORMER CO |
22558 | COAST/ADVANCED CHIP MAGNETICS INC. D |
97942 | NORTHROP GRUMMAN SYSTEMS CORPORATION |
89870 | BERKSHIRE TRANSFORMER |
85323 | BALTIMORE TRANSFORMER COMPANY |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND SLOT SINGLE GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
ADAU | BODY HEIGHT | 3.780 INCHES NOMINAL |
CQLC | WINDING TAP LOCATION (NON-CORE) | NEUTRAL TAP SINGLE COMPONENT SINGLE PRIMARY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.400 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 150.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY AND 108.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY AND 132.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 19 TAB, SOLDER LUG |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ADAQ | BODY LENGTH | 4.320 INCHES NOMINAL |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.440 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CWJS | WINDING OPERATING VOLTAGE | 208.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ADAT | BODY WIDTH | 3.060 INCHES NOMINAL |
CRBZ | WINDING OPERATING CURRENT | 770.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 60.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ABTD | MOUNTING SLOT WIDTH | 0.220 INCHES NOMINAL SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 770.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 30.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |