Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
42M1504 54418 A 5 9 5 KE
S34307 72149 A 3 2 5 TX
42M1504 72149 A 5 9 5 TX

CAGE Information

Code Company
54418 MILTOPE CORPORATION DBA VT MILTOPE
72149 ELECTRONIC TRANSFORMER CORP.

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ADAU BODY HEIGHT 3.781 INCHES NOMINAL
CQLC WINDING TAP LOCATION (NON-CORE) MULTIPLE TAPS W/CENTER TAP SINGLE COMPONENT 1ST SECONDARY
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND SINGLE GROUP
ADAQ BODY LENGTH 3.500 INCHES NOMINAL
ADAT BODY WIDTH 3.000 INCHES NOMINAL
AARG RELIABILITY INDICATOR NOT ESTABLISHED
CWJS WINDING OPERATING VOLTAGE 22.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
AKNA INCLOSURE TYPE HERMETICALLY SEALED
AXGY MOUNTING METHOD THREADED STUD SINGLE GROUP
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT
CRBZ WINDING OPERATING CURRENT 3.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY
CWJS WINDING OPERATING VOLTAGE 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
ACZB FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
CMLP THREAD QUANTITY PER INCH 32 SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 4.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY AND 52.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY AND 56.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
THSD THREAD SERIES DESIGNATOR UNF SINGLE GROUP
AAJD THREAD CLASS (NON-CORE) 2A SINGLE GROUP
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT 2ND SECONDARY
TTQY TERMINAL TYPE AND QUANTITY 10 SOLDER STUD
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CRBZ WINDING OPERATING CURRENT 1.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY
CQJX NOMINAL THREAD SIZE 0.190 INCHES SINGLE GROUP

Similar Parts

42M1504 , 42M1504 , 5950-00-898-9111 , 5950008989111 , 008989111 , 42M1504 , S34307 , 42M1504 ,