Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
172059-000 81413 A 5 2 5 TX
73C828-001 72964 A 5 2 6 TX
73C828-001 04660 A 3 2 A TX
8201425-001 04660 A 5 2 5 KE
73C828-001 90095 A 5 2 6 TX

CAGE Information

Code Company
04660 AIL SYSTEMS INC SUB OF EATON CORP
81413 BAE SYSTEMS INFORMATION AND ELECTRON
72964 ROBERT M HADLEY COMPANY INC
90095 PULSE ELECTRONICS DBA PULSE COMPONEN

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CWJS WINDING OPERATING VOLTAGE 39.20 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
CQJX NOMINAL THREAD SIZE 0.164 INCHES 4TH GROUP
ADAT BODY WIDTH 2.734 INCHES MINIMUM AND 2.766 INCHES MAXIMUM
CRBZ WINDING OPERATING CURRENT 743.0 MILLIAMPERES NOMINAL B SINGLE COMPONENT 1ST SECONDARY
AAJD THREAD CLASS (NON-CORE) 2B ALL GROUPINGS
ACZC INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT
AKNA INCLOSURE TYPE FULLY INCLOSED
TEST TEST DATA DOCUMENT 04660-73C828 DRAWING
CQJX NOMINAL THREAD SIZE 0.112 INCHES 2ND GROUP
CQJX NOMINAL THREAD SIZE 0.138 INCHES 1ST GROUP
ACZD TRANSFORMER WINDING CONNECTION TYPE DELTA-WYE
CQJX NOMINAL THREAD SIZE 0.112 INCHES 3RD GROUP
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND ALL GROUPINGS
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.734 INCHES MINIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP AND 2.766 INCHES MAXIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP
AXGY MOUNTING METHOD THREADED HOLE ALL GROUPINGS
AARG RELIABILITY INDICATOR NOT ESTABLISHED
TTQY TERMINAL TYPE AND QUANTITY 13 TURRET
ABKW OVERALL HEIGHT 1.922 INCHES MINIMUM AND 1.954 INCHES MAXIMUM
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.234 INCHES MINIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP AND 2.266 INCHES MAXIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP
CRMJ WINDING POWER RATING 29.13 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
AKPV MOUNTING FACILITY QUANTITY 2 1ST GROUP
CRBZ WINDING OPERATING CURRENT 4.0 AMPERES NOMINAL B SINGLE COMPONENT 2ND SECONDARY
CRMJ WINDING POWER RATING 26.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
ACZB FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
THSD THREAD SERIES DESIGNATOR UNC ALL GROUPINGS
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.115 INCHES MINIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP AND 2.135 INCHES MAXIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP
AKPV MOUNTING FACILITY QUANTITY 4 2ND GROUP
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.052 INCHES MINIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP AND 1.072 INCHES MAXIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP
AEJN DISTANCE BETWEEN MOUNTING FACILITY CENTERS 2.234 INCHES MINIMUM SINGLE MOUNTING FACILITY 1ST CENTER GROUP AND 2.266 INCHES MAXIMUM SINGLE MOUNTING FACILITY 1ST CENTER GROUP
AKPV MOUNTING FACILITY QUANTITY 4 3RD GROUP
ADAQ BODY LENGTH 3.609 INCHES MINIMUM AND 3.641 INCHES MAXIMUM
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP W/NEUTRAL TAP SINGLE COMPONENT 1ST SECONDARY
AEHZ MAXIMUM OPERATING TEMP 170.0 DEG CELSIUS
AKPV MOUNTING FACILITY QUANTITY 4 4TH GROUP
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.234 INCHES MINIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP AND 2.266 INCHES MAXIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.734 INCHES MINIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP AND 2.766 INCHES MAXIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP
CWJS WINDING OPERATING VOLTAGE 6.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
CWJS WINDING OPERATING VOLTAGE 198.90 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY

Similar Parts

73C828-001 , 73C828001 , 5950-00-945-0650 , 5950009450650 , 009450650 , 172059-000 , 73C828-001 , 73C828-001 , 8201425-001 , 73C828-001 ,