Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
420-7010-00 30072 F 3 9 A TX
A1-12828 95970 A 5 9 5 TX
420-7010-02 30072 F 5 9 5 TX
A1-12828 53854 A C 1 5 ZZ 9X

CAGE Information

Code Company
30072 EMERSON ELECTRIC CO DORIC SCIENTIFIC
95970 MTE CORP MILWAUKEE TRANSFORMER CO
53854 MAGNESPEC INC.

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
ACZB FREQUENCY RATING 48.0 HERTZ MINIMUM SINGLE COMPONENT AND 62.0 HERTZ MAXIMUM SINGLE COMPONENT
AKNA INCLOSURE TYPE FULLY INCLOSED
AKPV MOUNTING FACILITY QUANTITY 2 SINGLE GROUP
AEJN DISTANCE BETWEEN MOUNTING FACILITY CENTERS 1.490 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.510 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
AXGY MOUNTING METHOD FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP
AARG RELIABILITY INDICATOR NOT ESTABLISHED
TTQY TERMINAL TYPE AND QUANTITY 8 WIRE LEAD
ABKW OVERALL HEIGHT 2.090 INCHES MINIMUM AND 2.150 INCHES MAXIMUM
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT SINGLE SECONDARY
BPLC WINDING FUNCTION AND QUANTITY 2 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
ABHP OVERALL LENGTH 2.220 INCHES MINIMUM AND 2.280 INCHES MAXIMUM
ABMK OVERALL WIDTH 1.865 INCHES MINIMUM AND 1.885 INCHES MAXIMUM
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
CBBL FEATURES PROVIDED TINNED WIRE LEADS
CWJS WINDING OPERATING VOLTAGE 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL PRIMARY
ABTB MOUNTING HOLE DIAMETER 0.115 INCHES MINIMUM SINGLE GROUP AND 0.135 INCHES MAXIMUM SINGLE GROUP

Similar Parts