Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
03799 15634 A 5 2 5 TX
13089 53854 A 5 2 6 TX
905867-1 06481 A 3 2 A TX
905867-0001 06481 A 3 2 4 9Z

CAGE Information

Code Company
06481 NORTHROP GRUMMAN GUIDANCE AND ELECTR
15634 MAGNETIKA INC
53854 MAGNESPEC INC.

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 0.920 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 0.940 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
AKNA INCLOSURE TYPE FULLY INCLOSED
PKWT UNPACKAGED UNIT WEIGHT (NON-CORE) 350.0 GRAMS
CRMJ WINDING POWER RATING 13.8 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY
FEAT SPECIAL FEATURES SECONDARY TERMINALS SPLIT AND BROUGHT OUT TO TWO TERMINALS EACH
ABTB MOUNTING HOLE DIAMETER 0.143 INCHES MINIMUM SINGLE GROUP AND 0.149 INCHES MAXIMUM SINGLE GROUP
AARG RELIABILITY INDICATOR NOT ESTABLISHED
ADAT BODY WIDTH 1.230 INCHES MINIMUM AND 1.270 INCHES MAXIMUM
AEHZ MAXIMUM OPERATING TEMP 130.0 DEG CELSIUS
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
TEST TEST DATA DOCUMENT 06481-905867 DRAWING
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
ABKW OVERALL HEIGHT 1.050 INCHES MINIMUM AND 1.090 INCHES MAXIMUM
AXGY MOUNTING METHOD UNTHREADED HOLE SINGLE GROUP
CRBZ WINDING OPERATING CURRENT 529.0 MILLIAMPERES NOMINAL B SINGLE COMPONENT SINGLE SECONDARY
CWJS WINDING OPERATING VOLTAGE 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
TTQY TERMINAL TYPE AND QUANTITY 7 TURRET
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.170 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.190 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ABHP OVERALL LENGTH 3.480 INCHES MINIMUM AND 3.520 INCHES MAXIMUM
ACZB FREQUENCY RATING 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 26.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY

Similar Parts