Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
SBW,CAT.N0.W100 F0RM 55814 F C 1 6 ZZ AC
A404299 35550 A 5 2 5 TX
SBW,CAT.NO.W100 FORM R 28455 A 3 2 E TX

CAGE Information

Code Company
28455 HEVI DUTY ELECTRIC SOLA BASIC INDUST
55814 SOLA BASIC INDUSTRIES INC SOLA ELECT
35550 LEGION INDUSTRIES INC. DBA LEGION

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
ADAU BODY HEIGHT 2.875 INCHES NOMINAL
AKNA INCLOSURE TYPE FULLY INCLOSED
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ADAQ BODY LENGTH 3.766 INCHES NOMINAL
AXGY MOUNTING METHOD SLOT SINGLE GROUP
AARG RELIABILITY INDICATOR NOT ESTABLISHED
CWJS WINDING OPERATING VOLTAGE 240.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY
CWJS WINDING OPERATING VOLTAGE 480.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
TTQY TERMINAL TYPE AND QUANTITY 4 SCREW
ACZB FREQUENCY RATING 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
CRBZ WINDING OPERATING CURRENT 208.3 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.813 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
PKWT UNPACKAGED UNIT WEIGHT (NON-CORE) 3.750 POUNDS
ABTD MOUNTING SLOT WIDTH 0.203 INCHES NOMINAL SINGLE GROUP
ACZF MAXIMUM TRANSFORMER POWER RATING 100.0 VOLT-AMPERE SINGLE COMPONENT
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
ADAT BODY WIDTH 3.375 INCHES NOMINAL

Similar Parts