National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
KGB2301-1 02750 A 5 9 A TX
LO3886 16236 A 5 2 A ZZ
KGB2301-1 06RP6 A 3 1 1 ZZ

CAGE Information

Code Company
02750 EATON AEROSPACE LLC DIV ELECTRICAL S
16236 DLA LAND AND MARITIME
06RP6 DRS CONSOLIDATED CONTROLS, INC.

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CQLC WINDING TAP LOCATION (NON-CORE) TAP W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY
CQLC WINDING TAP LOCATION (NON-CORE) NEUTRAL TAP SINGLE COMPONENT 2ND SECONDARY
CWJS WINDING OPERATING VOLTAGE 2.83 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 20.30 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
CRTL CRITICALITY CODE JUSTIFICATION ZZZY
FEAT SPECIAL FEATURES ITEM MUST COMPLY WITH REQUIREMENTS OF DESC PRODUCTION STANDARD NO. L03886
AKNA INCLOSURE TYPE FULLY INCLOSED
ADAQ BODY LENGTH 0.525 INCHES MAXIMUM
CWJS WINDING OPERATING VOLTAGE 3.40 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
TTQY TERMINAL TYPE AND QUANTITY 9 PIN
ACZF MAXIMUM TRANSFORMER POWER RATING 25.0 VOLT-AMPERE SINGLE COMPONENT
AARG RELIABILITY INDICATOR NOT ESTABLISHED
ZZZY REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS REF NUMBER DIFFERENTIATING MATERIAL WILL BE IAW NAVAL INVENTORY CONTROL POINT ACTIVITY HX QUALITY CONYROL,MANUFACTURING AND TESTING SPECIFICATIONS AVAILABLE AT THE DLA ICP
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 17.07 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY AND 37.55 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
AXGY MOUNTING METHOD PLUG-IN SINGLE GROUP
ACZB FREQUENCY RATING 50.0 KILOHERTZ NOMINAL SINGLE COMPONENT OR 60.0 KILOHERTZ NOMINAL SINGLE COMPONENT
AEHZ MAXIMUM OPERATING TEMP 90.0 DEG CELSIUS