National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
REACTOR-TRANSFORMER
Definition:
A COMPONENT CONSISTING OF TWO OR MORE ELECTRICALLY DISTINCT ITEMS. ONE OR MORE ITEMS ARE MADE OF ONE OR MORE COILS WHICH FUNCTION AS A REACTOR; AT LEAST ONE OTHER ITEM IS MADE OF A TAPPED COIL OR TWO OR MORE COILS WHICH FUNCTION AS A TRANSFORMER. THE ITEMS MAY HAVE A COMMON CORE, BUT ARE NOT MAGNETICALLY COUPLED.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
230030-1 | 13058 | A | 1 | 2 | 2 | MC | ||
230030 | 13058 | A | D | 9 | 2 | ZZ | ||
SR1003 | 13058 | A | 3 | 2 | 2 | ZZ |
CAGE Information
Code | Company |
---|---|
13058 | SORA POWER INC. |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AXGY | MOUNTING METHOD | THREADED HOLE 2ND GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE 1ST GROUP |
ASKA | COMPONENT NAME AND QUANTITY | 1 COIL AND 1 TRANSFORMER |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
CWJS | WINDING OPERATING VOLTAGE | 16000.00 AC POUNDS PER HOUR WET 2ND COMPONENT SINGLE SECONDARY |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS ALL WINDING |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND 2ND GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.312 INCHES MINIMUM 1ST GROUP AND 0.319 INCHES MAXIMUM 1ST GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 6 2ND GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.594 INCHES NOMINAL 2ND MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 6.430 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 12 THREADED STUD |
ABMK | OVERALL WIDTH | 4.840 INCHES NOMINAL |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES 2ND GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 2 1ST GROUP |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.594 INCHES NOMINAL 1ST MOUNTING FACILITY SINGLE CENTER GROUP |
ABHP | OVERALL LENGTH | 11.120 INCHES NOMINAL |
CRBZ | WINDING OPERATING CURRENT | 1900.0 AMPERES NOMINAL B AND BETTER DROP SIDING 1ST COMPONENT ALL WINDING |
AAJD | THREAD CLASS (NON-CORE) | 2A 2ND GROUP |
ACZH | PRIMARY TO SECONDARY TURN RATIO | 1 TO 17 2ND COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 300.0 AMPERES NOMINAL B AND BETTER DROP SIDING 2ND COMPONENT SINGLE SECONDARY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 11.000 INCHES NOMINAL 2ND MOUNTING FACILITY SINGLE CENTER GROUP |
CWJS | WINDING OPERATING VOLTAGE | 1000.00 AC POUNDS PER HOUR WET 1ST COMPONENT ALL WINDING |
CRBZ | WINDING OPERATING CURRENT | 1900.0 AMPERES NOMINAL B AND BETTER DROP SIDING 2ND COMPONENT SINGLE PRIMARY |
THSD | THREAD SERIES DESIGNATOR | UNC 2ND GROUP |