Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
1358AS152-1 30003 A 3 2 A TX
TW-TO-199-121 02640 A 5 2 6 ZZ
LD-45 07183 A 5 9 5 TX

CAGE Information

Code Company
02640 MAGNETIKA
30003 NAVAL AIR SYSTEMS COMMAND
07183 DECCO INC

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY
CWJS WINDING OPERATING VOLTAGE 230.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
CRMJ WINDING POWER RATING 44.8 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY
AXGY MOUNTING METHOD SLOT SINGLE GROUP
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
AARG RELIABILITY INDICATOR NOT ESTABLISHED
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.437 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.563 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ABKW OVERALL HEIGHT 2.437 INCHES MINIMUM AND 2.563 INCHES MAXIMUM
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
ABHP OVERALL LENGTH 3.000 INCHES NOMINAL
ABMK OVERALL WIDTH 2.687 INCHES MINIMUM AND 2.813 INCHES MAXIMUM
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
TTQY TERMINAL TYPE AND QUANTITY 5 WIRE LEAD
CRBZ WINDING OPERATING CURRENT 390.0 MILLIAMPERES NOMINAL B SINGLE COMPONENT SINGLE SECONDARY
AKNA INCLOSURE TYPE OPEN
ABTD MOUNTING SLOT WIDTH 0.125 INCHES MINIMUM SINGLE GROUP AND 0.251 INCHES MAXIMUM SINGLE GROUP
ACZB FREQUENCY RATING 60.0 HERTZ NOMINAL SINGLE COMPONENT

Similar Parts

TW-TO-199-121 , TWTO199121 , 5950-01-321-1907 , 5950013211907 , 013211907 , 1358AS152-1 , TW-TO-199-121 , LD-45 ,