Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
726908-1 21562 A 5 2 5 TX
11-00069-001 21562 A 3 2 A ZZ

CAGE Information

Code Company
21562 GENERAL DYNAMICS OTS AEROSPACE INC.

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
AKNA INCLOSURE TYPE FULLY INCLOSED
CRMJ WINDING POWER RATING 328.6 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
CRBZ WINDING OPERATING CURRENT 2.8 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY
ACZB FREQUENCY RATING 28.5 KILOHERTZ NOMINAL SINGLE COMPONENT
AEHZ MAXIMUM OPERATING TEMP 134.0 DEG CELSIUS
CRMJ WINDING POWER RATING 95.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
BPLC WINDING FUNCTION AND QUANTITY 4 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT
AARG RELIABILITY INDICATOR NOT ESTABLISHED
CRMJ WINDING POWER RATING 339.6 VOLTS-AMPERES SINGLE COMPONENT ALL PRIMARY
ABTB MOUNTING HOLE DIAMETER 0.110 INCHES MINIMUM SINGLE GROUP AND 0.130 INCHES MAXIMUM SINGLE GROUP
ADAU BODY HEIGHT 1.260 INCHES MINIMUM AND 1.300 INCHES MAXIMUM
ABHP OVERALL LENGTH 1.200 INCHES MAXIMUM
TTQY TERMINAL TYPE AND QUANTITY 13 PIN AND 2 WIRE LEAD
CWJS WINDING OPERATING VOLTAGE 56.56 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
AXGY MOUNTING METHOD UNTHREADED HOLE SINGLE GROUP
CRBZ WINDING OPERATING CURRENT 5.81 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY
CRBZ WINDING OPERATING CURRENT 30.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT ALL PRIMARY
ABMK OVERALL WIDTH 0.594 INCHES MAXIMUM
CWJS WINDING OPERATING VOLTAGE 11.32 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL PRIMARY
CWJS WINDING OPERATING VOLTAGE 33.93 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT 2ND SECONDARY
CBBL FEATURES PROVIDED COLOR CODED LEAD
CBME CUBIC MEASURE (NON-CORE) 0.92 CUBIC INCHES

Similar Parts

11-00069-001 , 1100069001 , 5950-01-324-2405 , 5950013242405 , 013242405 , 726908-1 , 11-00069-001 ,