National Stock Number (NSN) Output Data
Definition:
AN ITEM GENERALLY CONSISTING OF ONE OR MORE TURNS OF WIRE OR SIMILAR CONDUCTIVE MATERIAL (IN SPECIAL CASES IT MAY BE CONSIDERED AS A PARTIAL TURN). IT IS SPECIFICALLY DESIGNED TO CONCENTRATE MAGNETIC FLUX GENERATED BY THE FLOW OF AN ELECTRIC CURRENT, TO INDUCE IN ITSELF AN ELECTROMOTIVE FORCE, AND TO ADD OR SUBTRACT INDUCTIVE REACTANCE IN A CIRCUIT. IT MAY INCLUDE TUNING DEVICES, INTEGRAL RESISTORS AND CAPACITORS; HOWEVER, EXCLUDES FILTER (AS MODIFIED). FOR COILS WOUND ON RESISTORS WHICH ARE DESIGNED TO BE INSERTED INTO THE CIRCUIT OF A RADIO FREQUENCY STAGE TO SUPPRESS HIGH FREQUENCY PARASITIC OSCILLATIONS, SEE SUPPRESSOR, PARASITIC..
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
11-00035-001 | 21562 | A | 3 | 2 | 5 | ZZ | ||
727938-1 | 21562 | A | 5 | 2 | 5 | TX |
CAGE Information
Code | Company |
---|---|
21562 | GENERAL DYNAMICS OTS AEROSPACE INC. |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT ALL WINDING |
ADAQ | BODY LENGTH | 0.350 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKDX | WINDING QUANTITY | 2 SINGLE COMPONENT |
TTQY | TERMINAL TYPE AND QUANTITY | 4 WIRE LEAD |
ADAV | OVERALL DIAMETER | 0.700 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ACZR | CORE CONSTRUCTION | S0LID SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 1.00 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL WINDING |
ACZB | FREQUENCY RATING | 100.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
ACYV | INDUCTANCE RATING | 50.40 MICROHENRIES MINIMUM SINGLE COMPONENT ALL WINDING AND 75.60 MICROHENRIES MAXIMUM SINGLE COMPONENT ALL WINDING |
AEHZ | MAXIMUM OPERATING TEMP | 120.0 DEG CELSIUS |
TEST | TEST DATA DOCUMENT | 16340-11-00035 DRAWING |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.6 AMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT ALL WINDING |
CRGS | DC RESISTANCE RATING IN OHMS | 0.145 SINGLE COMPONENT ALL WINDING |