National Stock Number (NSN) Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
V500BTZ13JK | 30882 | A | 3 | 2 | E | TX |
CAGE Information
Code | Company |
---|---|
30882 | MICRON INDUSTRIES CORP |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 500.0 VOLT-AMPERE SINGLE COMPONENT |
PKWT | UNPACKAGED UNIT WEIGHT (NON-CORE) | 16.800 POUNDS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
CBME | CUBIC MEASURE (NON-CORE) | 124.688 CUBIC INCHES |
CWJS | WINDING OPERATING VOLTAGE | 110.00 AC POUNDS PER HOUR DRY SINGLE COMPONENT SINGLE SECONDARY AND 220.00 AC POUNDS PER HOUR DRY SINGLE COMPONENT ALL PRIMARY AND 120.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT SINGLE SECONDARY |
ABHP | OVERALL LENGTH | 5.250 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AEHZ | MAXIMUM OPERATING TEMP | 105.0 DEG CELSIUS |
AXGY | MOUNTING METHOD | SLOT SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 4.35 AMPERES NOMINAL B SINGLE COMPONENT SINGLE SECONDARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CWJS | WINDING OPERATING VOLTAGE | 240.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT ALL PRIMARY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ABTD | MOUNTING SLOT WIDTH | 0.312 INCHES NOMINAL SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
ABKW | OVERALL HEIGHT | 4.750 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 5.000 INCHES NOMINAL |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TERMINAL BLOCK W/SCREWS |
FEAT | SPECIAL FEATURES | PRIMARY IS SUPPLIED WITH J-2 TYPE JUMPERS; SECONDARY HAS TYPE K FUSE CLIPS |