National Stock Number (NSN) Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
ITP-1452-21 | 09969 | A | 5 | 2 | 6 | TX | ||
10124753-104 | 94580 | A | 3 | 2 | A | TX |
CAGE Information
Code | Company |
---|---|
09969 | VISHAY DALE ELECTRONICS INC. DIV VIS |
94580 | HONEYWELL INTERNATIONAL INC DBA HONE |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 15.80 DC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 5.50 DC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
ADAV | OVERALL DIAMETER | 1.510 INCHES MAXIMUM |
CBME | CUBIC MEASURE (NON-CORE) | 4.29 CUBIC INCHES |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 0.97 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 14.3 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
ACZB | FREQUENCY RATING | 10.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CRMJ | WINDING POWER RATING | 12.0 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
CRBZ | WINDING OPERATING CURRENT | 2.6 AMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 3RD SECONDARY |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 62.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 31.60 DC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY |
CBBL | FEATURES PROVIDED | W/RECTIFIER |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT 1ST SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 14 PIN |
CRBZ | WINDING OPERATING CURRENT | 96.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 2ND SECONDARY |
AFFL | MOUNTING BOLT CIRCLE DIAMETER | 1.350 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ADAQ | BODY LENGTH | 0.600 INCHES MAXIMUM |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 70.70 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | FUNGUS RESISTANT AND MOISTURE RESISTANT |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |
CRMJ | WINDING POWER RATING | 2.88 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 0.38 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 30.00 DC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |