National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
TRANSFORMER , POWER
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number |
CAGE |
Status |
RNCC |
RNVC |
DAC |
RNAAC |
MSDS |
SADC |
MIL-T-27/320 |
81349 |
M |
4 |
1 |
4 |
9Z |
|
|
M27/320-12 |
81349 |
M |
2 |
2 |
4 |
9Z |
|
|
CAGE Information
Code |
Company |
81349 |
MILITARY SPECIFICATIONS PROMULGATED |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
ACZB |
FREQUENCY RATING |
50.0 HERTZ MINIMUM SINGLE COMPONENT AND 60.0 HERTZ MAXIMUM SINGLE COMPONENT |
AAJD |
THREAD CLASS (NON-CORE) |
2B SINGLE GROUP |
ABHP |
OVERALL LENGTH |
3.719 INCHES MINIMUM AND 3.781 INCHES MAXIMUM |
AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
TTQY |
TERMINAL TYPE AND QUANTITY |
5 WIRE HOOK |
ABMK |
OVERALL WIDTH |
3.099 INCHES MINIMUM AND 3.161 INCHES MAXIMUM |
AAJF |
THREAD DIRECTION (NON-CORE) |
RIGHT-HAND SINGLE GROUP |
CWJS |
WINDING OPERATING VOLTAGE |
35.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
2.424 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.456 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
AXGY |
MOUNTING METHOD |
THREADED HOLE SINGLE GROUP |
ABKW |
OVERALL HEIGHT |
5.255 INCHES NOMINAL |
CRBZ |
WINDING OPERATING CURRENT |
4.52 AMPERES NOMINAL B SINGLE COMPONENT SINGLE SECONDARY |
ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
2.734 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.766 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
ACZF |
MAXIMUM TRANSFORMER POWER RATING |
160.0 VOLT-AMPERE SINGLE COMPONENT |
CWJS |
WINDING OPERATING VOLTAGE |
115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
THSD |
THREAD SERIES DESIGNATOR |
UNF SINGLE GROUP |
CQJX |
NOMINAL THREAD SIZE |
0.190 INCHES SINGLE GROUP |
Similar Parts