National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
OSCILLATOR , NONCRYSTAL CONTROLLED
Definition:
AN OSCILLATOR WHOSE OPERATING FREQUENCY(IES) IS CONTROLLED BY AN ELECTRONIC DEVICE OTHER THAN A CRYSTAL UNIT, QUARTZ. FOR AN OSCILLATOR CONTROLLED BY A CRYSTAL, SEE OSCILLATOR (1), CRYSTAL CONTROLLED. SEE ALSO GENERATOR, SIGNAL; AND CALIBRATOR, FREQUENCY. EXCLUDES FREQUENCY SUPPLY, TELEPHONE CARRIER; RESONATOR, TUNING FORK; AND OSCILLATOR, PULSE DELAY.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
NH314-31 | 16681 | A | 5 | 2 | 5 | TX | ||
NH31401-31 | 16681 | A | 3 | 2 | 1 | TX |
CAGE Information
Code | Company |
---|---|
16681 | GREENRAY INDUSTRIES INC. |
Federal Supply Class
Title
OSCILLATORS AND PIEZOELECTRIC CR
Inclusions:
INCLUDES CRYSTAL UNITS, PROCESSED UNMOUNTED CRYSTALS, CRYSTAL CONTROLLED OSCILLATORS AND NONCRYSTAL CONTROLLED OSCILLATORS
Exclusions:
EXCLUDES CRYSTAL CONTROLLED OSCILLATORS AND NONCRYSTAL CONTROLLED OSCILLATORS WHICH MEET THE DEFINITION OF THE TERM "ELECTRONIC MODULE" AS DEFINED FOR FSC 5963 AND MICROCIRCUITS
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
BHTN | IMPEDANCE RATING PER CHANNEL | 1000.000 OHMS OUTPUT CHANNEL |
BHTK | SIGNAL VOLTAGE RATING PER CHANNEL | NOT RATED |
BJBW | CONNECTION CONTACT TYPE AND QUANTITY | 5 WIRE LEAD TERMINALS EXTERNAL |
AGTA | BASIC SHAPE STYLE | RECTANGULAR OR SQUARE |
BKFB | EXTERNAL DC OPERATING VOLTAGE IN VOLTS | 15.0 NOMINAL SINGLE VOLTAGE |
AMQY | INSTALLATION DESIGN | MECHANICAL |
AJKH | IDENTIFICATION DESIGNATOR | NH314-31-16681 |
BHTJ | AVERAGE POWER RATING PER CHANNEL | 1.0 MILLIWATTS OUTPUT |
BJBM | MAXIMUM CONTINUOUS OPERATING TIME IN HOURS | NOT RATED |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | NOT RATED |
AKAE | MAXIMUM OPERATING ALTITUDE RATING | NOT RATED |
AFDP | SHOCK RESISTANCE RATING IN GRAVITATIONAL UNITS | NOT RATED |
AFSU | AVERAGE LIFE MEASUREMENT | NOT RATED |
BHTH | ATTENUATION IN DECIBELS | NOT RATED |
BHTL | OVERALL GAIN | NOT RATED |
BHTB | FREQUENCY PER CHANNEL | 101.4 MEGAHERTZ CERIUM MEGAHERTZ |
ABHP | OVERALL LENGTH | 4.470 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.000 INCHES NOMINAL |
BHSX | CIRCUIT CONSTRUCTION TYPE | SOLID STATE |
AKNA | INCLOSURE TYPE | ENCASED |
BHTD | FREQUENCY ADJUSTMENT TYPE | CONTINUOUS |
AFGA | OPERATING TEMP RANGE | NOT RATED |
BJBP | CONNECTION TYPE AND LOCATION | WIRE LEAD TERMINALS BOTTOM |
ABMK | OVERALL WIDTH | 2.000 INCHES NOMINAL |