National Stock Number (NSN) Output Data
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
AMS-DTL-23053/11 | 81343 | A | 5 | 1 | E | ZZ | ||
M23053/11-114-C | 81349 | M | 5 | 9 | 4 | CX | ||
S9051-4-000 | 70210 | A | 5 | 2 | 1 | CX | ||
FIT-400-4 | 92194 | Y | 5 | 1 | E | CX | ||
M23053/11-114-C | 81343 | A | 3 | 2 | E | ZZ | ||
PENNTUBE2SMT4 | 06090 | A | C | 1 | 9 | TU | ||
MIL-I-23053/11 | 81349 | M | 5 | 9 | 4 | CX |
CAGE Information
Code | Company |
---|---|
06090 | TYCO ELECTRONICS CORPORATION DIV RAY |
81343 | SOCIETY OF AUTOMOTIVE ENGINEERS INC |
81349 | MILITARY SPECIFICATIONS PROMULGATED |
70210 | HONEYWELL INTERNATIONAL INC. DBA HON |
92194 | ALPHA WIRE CORP |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AFZN | RECOVERED WALL THICKNESS | 0.011 INCHES NOMINAL |
STYL | STYLE DESIGNATOR | SHRINKABLE |
AFZM | RECOVERED INSIDE DIAMETER | 0.226 INCHES MAXIMUM |
AFZL | EXPANDED INSIDE DIAMETER | 0.290 INCHES MINIMUM |
FLEX | FLEXIBILITY | FLEXIBLE |
ABHP | OVERALL LENGTH | ANY ACCEPTABLE |
ABJH | TEMP RATING | -67.0 DEG CELSIUS AND 200.0 DEG CELSIUS |
CQBC | MINIMUM TENSILE STRENGTH | 2000 POUNDS PER SQUARE INCH |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 500.0 VOLTS PER MIL /0.001 INCH/ |
HUES | COLOR | CLEAR |
ADZC | ENVIRONMENTAL PROTECTION | CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND WATER RESISTANT |
MATL | MATERIAL | PLASTIC,FLUORINATED ETHYLENE PROPYLENE,MIL-I-23053/11,CLASS 1 |
AGAU | HEAT SHRINKAGE RATING IN PERCENT | 22.1 |