National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
DUMMY LOAD , ELECTRICAL

Definition:

A SPECIFIC ELECTRICAL ELEMENT OR SET OF ELECTRICAL ELEMENTS THAT ARE CONNECTED TOGETHER TO FORM A FIXED ARRANGEMENT AND USED AS A SUBSTITUTE LOAD FOR TERMINATING AN ELECTRICAL CIRCUIT. A DUMMY LOAD CONTAINS ALL THE ESSENTIAL ELECTRICAL CHARACTERISTICS NECESSARY TO TERMINATE THE CIRCUIT BUT DOES NOT FUNCTION IN THE SAME MANNER AS THE LOAD WHICH IT REPLACES. EXAMPLES ARE RESISTORS USED TO REPLACE ANTENNAS, BATTERIES, LOUDSPEAKERS, OR THE LIKE. INCLUDES SINGLE PORT TERMINATIONS OF TWIN LEAD, COAXIAL AND WAVEGUIDE TRANSMISSION LINES AS LOW POWER TERMINATIONS OF A SECTION OF A TRANSMISSION SYSTEM IN A SPECIFIED MANNER. INCLUDES DUMMY LOADS WHEN ARRANGED IN A GROUP OR BANK. EXCLUDES POWER ABSORBERS. SEE ALSO LOAD BANK, ELECTRICAL.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
RFD0609-819B 94375 A 5 2 3 TX
7534208-2 99971 A 3 9 1 TX

CAGE Information

Code Company
94375 AUTOMATIC CONNECTOR
99971 LOCKHEED MARTIN CORP NAVAL ELECTRONI

Federal Supply Class

Title

ANTENNAS, WAVEGUIDES, AND RELATE

Inclusions:

INCLUDES AERIALS; MASTS; TOWER EQUIPMENT; ATTENUATORS; COUPLERS; TRANSMISSION LINES.

Exclusions:

EXCLUDES TOWER STRUCTURES.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKRZ TERMINATION TYPE CONNECTION COAXIAL
AKRZ TERMINATION TYPE CONNECTION COAXIAL
AJDB POWER RATING ANY ACCEPTABLE
ARNH OPERATING POSITION ALL POSITIONS
STYL STYLE DESIGNATOR COAXIAL MOUNTED
BFMF COOLING METHOD SELF-COOLED
AHUC COAXIAL CONNECTOR SERIES DESIGNATION BNC
AHTW VOLTAGE STANDING WAVE RATIO ANY ACCEPTABLE
AFGQ FREQUENCY RANGE RATING ANY ACCEPTABLE
ACYW IMPEDANCE RATING IN OHMS NOT RATED
AHUD CONNECTOR END DESIGN NEUTER
ABHP OVERALL LENGTH 0.468 INCHES NOMINAL
ADAV OVERALL DIAMETER 0.373 INCHES NOMINAL

Similar Parts

RFD0609-819B , RFD0609819B , 5985-00-325-8278 , 5985003258278 , 003258278 , RFD0609-819B , 7534208-2 ,