Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
DUMMY LOAD , ELECTRICAL

Definition:

A SPECIFIC ELECTRICAL ELEMENT OR SET OF ELECTRICAL ELEMENTS THAT ARE CONNECTED TOGETHER TO FORM A FIXED ARRANGEMENT AND USED AS A SUBSTITUTE LOAD FOR TERMINATING AN ELECTRICAL CIRCUIT. A DUMMY LOAD CONTAINS ALL THE ESSENTIAL ELECTRICAL CHARACTERISTICS NECESSARY TO TERMINATE THE CIRCUIT BUT DOES NOT FUNCTION IN THE SAME MANNER AS THE LOAD WHICH IT REPLACES. EXAMPLES ARE RESISTORS USED TO REPLACE ANTENNAS, BATTERIES, LOUDSPEAKERS, OR THE LIKE. INCLUDES SINGLE PORT TERMINATIONS OF TWIN LEAD, COAXIAL AND WAVEGUIDE TRANSMISSION LINES AS LOW POWER TERMINATIONS OF A SECTION OF A TRANSMISSION SYSTEM IN A SPECIFIED MANNER. INCLUDES DUMMY LOADS WHEN ARRANGED IN A GROUP OR BANK. EXCLUDES POWER ABSORBERS. SEE ALSO LOAD BANK, ELECTRICAL.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
2521318-1 10001 A 3 2 1 HH

CAGE Information

Code Company
10001 NAVAIR AND NAVSEA MANAGED ORIGINAL D

Federal Supply Class

Title

ANTENNAS, WAVEGUIDES, AND RELATE

Inclusions:

INCLUDES AERIALS; MASTS; TOWER EQUIPMENT; ATTENUATORS; COUPLERS; TRANSMISSION LINES.

Exclusions:

EXCLUDES TOWER STRUCTURES.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKRZ TERMINATION TYPE CONNECTION COAXIAL
ACYW IMPEDANCE RATING IN OHMS 51.0 NOMINAL
AAQF AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER 85.0
ARNH OPERATING POSITION ALL POSITIONS
STYL STYLE DESIGNATOR COAXIAL MOUNTED
BFMF COOLING METHOD SELF-COOLED
ABHP OVERALL LENGTH 1.375 INCHES NOMINAL
AJDB POWER RATING 0.500 WATTS AVERAGE
ADAV OVERALL DIAMETER 0.625 INCHES NOMINAL
FEAT SPECIAL FEATURES OPERATING FREQ 10.0 GHZ,CONNECTION THD SZ 0.4375-28 UNEF 2B

Similar Parts

2521318-1 , 25213181 , 5985-00-832-4138 , 5985008324138 , 008324138 , 2521318-1 ,