National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
SWITCH , WAVEGUIDE
Definition:
AN ITEM SPECIFICALLY DESIGNED FOR MECHANICALLY OR ELECTRONICALLY POSITIONING ONE OR MORE WAVEGUIDE SECTIONS SO AS TO COUPLE IT OR THEM TO OTHER SECTIONS IN A WAVEGUIDE SYSTEM. THE SWITCHING FUNCTION MAY BE OPERATED BY A MANUAL ACTUATOR, AN ELECTROMECHANICAL ACTUATOR OR BY MEANS OF AN ARRANGEMENT OF SEMICONDUCTORS AND PASSIVE CIRCUIT DEVICES. EXCLUDES RELAY, (AS MODIFIED).
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
HS06X51-1 | 24022 | A | 5 | 2 | 5 | KE | ||
290011P3 | 94117 | A | 3 | 2 | A | TX |
CAGE Information
Code | Company |
---|---|
24022 | TELEDYNE WIRELESS LLC DBA TELEDYNE M |
94117 | BAE SYSTEMS INFORMATION AND ELECTRON |
Federal Supply Class
Title
ANTENNAS, WAVEGUIDES, AND RELATE
Inclusions:
INCLUDES AERIALS; MASTS; TOWER EQUIPMENT; ATTENUATORS; COUPLERS; TRANSMISSION LINES.
Exclusions:
EXCLUDES TOWER STRUCTURES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AFGA | OPERATING TEMP RANGE | -55.0/+125.0 DEG CELSIUS |
AKQA | RF MAXIMUM VOLTAGE RATING | 150.0 VOLTS RMS |
ABHP | OVERALL LENGTH | 3.795 INCHES MAXIMUM |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES FLANGE CONNECTION FACILITY HOLE |
ABMK | OVERALL WIDTH | 2.390 INCHES NOMINAL |
AKPT | WAVEGUIDE FLANGE TYPE | CHOKE |
AEEA | SWITCH TYPE | NONTRANSFER |
AHTX | INSERTION LOSS IN DECIBELS | 0.80 SINGLE |
ABKW | OVERALL HEIGHT | 3.010 INCHES NOMINAL |
AKRC | COUPLING POSITION QUANTITY | 4 |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TURRET AND 1 PLUG, COAXIAL AND 1 RECTANGULAR FLANGE |
AKPC | ACTUATOR OPERATING METHOD | RELAY |
AKPP | SWITCHING TIME | 0.1 SECONDS |
AKNF | RF POWER HANDLING CAPABILITY | 4.0 WATTS AVERAGE SINGLE |
AHTW | VOLTAGE STANDING WAVE RATIO | 2.00 SINGLE |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE |
AKPJ | ACTUATOR VOLTAGE IN VOLTS | 150.0 NOMINAL |
THSD | THREAD SERIES DESIGNATOR | UNC FLANGE CONNECTION FACILITY HOLE |